Test Group |
Order of Test |
Examination or Test |
Test Method (Per MIL-STD-202) |
Post Test Requirements |
| IIA |
1 |
Voltage Drop |
Paragraph 4.6.8 of MIL-F-15733 |
Three percent of rated voltage max. |
| 2 |
Leakage Current |
UL 1283 |
Per applicable specification |
| 3 |
Temperature Rise |
MIL-F-15733 Paragraph 4.6.4 |
25°C max. |
| 4 |
Terminal Strength |
Method 211, Condition A |
No evidence of loosening or rupture 5 lb. applied force. Line Cords: 35 Lbs. |
| IIB |
1 |
Shock, Medium Impact |
Method 213, Condition G |
Must pass DWV and Insertion Loss |
| 2 |
Vibration, High Frequency |
Method 204, Condition A |
Monitor for shorts or open |
| 3 |
Thermal Shock |
Method 107, Test Condition A |
Pass 90% DWV IR to be 30% of initial |
| 4 |
Humidity |
Method 107, Condition B, except temperature equals 25°C |
Pass 90% DWV IR to be 30% of initial |
| III |
1 |
Life |
Method 108, Condition D 1.2 x Rated AC voltage at max. operating temp. or 1.4 x DC voltage |
Pass 90% DWV insulation resistance to be 30% of initial. |