Stock
Check

Signal & Power Integrity Components Business EMI & Surge Components & Modules

"R" level screening is performed by Spectrum Control's Hi-Rel Laboratory as detailed below. Customers requiring special tests may order to their own specifications or simply order to level R and then note additions or deviations.

 
 

"R" Level Test Sequence Summary



(100% testing unless otherwise specified)

  • Thermal Shock: 5 cycles from -55°C to +125°C in accordance with MIL-STD-202, Method 107D, Condition A.
  • Burn-in: 100 hours at 1.4x rated DC voltage, 125°C.
  • Seal Test: MIL-STD-202, Method 112, Test Condition A. Hermetic seal parts only.
  • Capacitance and Dissipation Factor: MIL-STD-202, Method 305, frequency 1kHz.
  • Dielectric Withstanding Voltage: 2.5 times the rated DC voltage for 5 ± 1 second at 25°C, with 50 mA maximum charging current.
  • Insulation Resistance: MIL-STD-202, Method 302, 125°C at rated DC voltage and room temperature (25°C). The 125°C requirement shall be 10% of the specified catalog IR at 25°C.
  • DC Resistance: MIL-STD-202, Method 303.
  • Insertion Loss Test — Sample per MIL-F-15733. At full rated load in accordance with MIL-STD-220. The minimum insertion loss shall be defined in the filter catalog.
  • Visual and Mechanical: in accordance with MIL-F-15733.
  • Marking: All filters which have successfully completed the test sequence shall be marked with an "R" in the second part of the number. For example, a standard SCI-2130-004 becomes SCI-R2130-004 and 9051-100- 0000 becomes 9051-R100-0000, and 51-719-011 becomes 51-R719-011 after completion of the Hi-Rel Level "R" Test Sequence.

Performance Tests

Class B Reliability Level Testing

 Contact the Quality Performance Testing Representative Contact a Quality Representative  

Contact the Compliance Testing Representative
To:
Compliance Testing Representative
From * :
Message * :
Optional Information
Name:
Company:
Address:
 
City:
State / Province:
Postal Code:
Country:
Phone:
* - Indicates a Required Field.
Spectrum Control Inc. respects the privacy of its website visitors.
All information recieved through our website will remain confidential
and will only be used to identify and better serve our customers.
Cookies are only used on our site to enhance and expedite the user's
experience within our web applications.
   Home   ::   About Us   ::   Contact Us   ::   Partners   ::   Corporate Site   ::   Privacy Policy   ::   Terms & Conditions   ::   Product Compliance   
 
Spectrum Sensors & Controls Inc.
Spectrum Signal & Power Integrity
Spectrum Microwave Components & Systems
Spectrum Power Management Systems
 
Spectrum Sensors
& Controls
Spectrum Signal
& Power Integrity
Spectrum Microwave
Components & Systems
Spectrum Power
Management Systems
 
EMI & Surge Components & Modules
8061 Avonia Road  ·  Fairview, PA  ·  Phone: 814-474-1571  ·  Fax: 814-474-3110
Copyright © 2006     Spectrum Control Spectrum Control, Inc.    All Rights Reserved